Performing an AS configuration on an Arria® 10 with corrupted or incorrect configuration data will cause the device to enter an unexpected state and JTAG access will be disabled.
To recover from this condition, you must issue a CONFIG_IO instruction to the Arria® 10 device to stop the AS configuration process and enable the JTAG port.
Please refer to the Knowledge Database below for a Jam STAPLE file that issues the CONFIG_IO instruction and an example of its execution.
(Why can't I access the Arria 10 device through the JTAG interface when using Active Serial configuration mode?
https://www.intel.com/content/www /us/en/programmable/support/support-resources/knowledge-base/solutions/rd02282016_156.html
--------------------
Category: Programming/Configuration
Tools:-
Device: Arria® 10