The following settings are recommended.
The following functions are available.
Latency from input to output is 3 clocks
- Multiplication result of input (dataa, datab) entered with accum_solad = H is treated as "first value" of the sum
(sum up to previous input is lost)
- Asynchronous reset Aclr0 (High Active) to zero all registers Aclr0 (High Active) resets all registers to 0.
Note that, as a general problem that must be considered in sum-of-products calculations for fixed-point numbers, how to set and handle data width and sign settings, rounding, bit shift, and overflow detection, while considering the nature of the data to be handled.
[Answer]
--------------------
Category: DSP
Tool: Quartus® Prime
Device: -